Quantitative bi-component T2* analysis of histologically normal Achilles tendons
Original Article, 58 - 62
doi: 10.11138/mltj/2015.5.2.058
Tag this article
Introduction: the aim of this pilot study was to implement ultrashort echo time (UTE) MRI with bicomponent analysis on grossly normal Achilles tendons with histologic correlation.
Materials and methods: six tendon samples which were grossly normal on visual inspection and palpation were harvested. A 2D UTE pulse sequence was implemented on a 3T MR scanner and bicomponent and single-component T2* analysis was performed. Tendon samples were histologically processed and evaluated.
Results: mean short T2* fraction was 79.2% (95% confidence interval [CI],70.1 – 88.3%), mean short T2* was 1.8 ms (95% CI, 1.3 – 2.3 ms), mean long T2* fraction was 20.8% (95% CI, 11.7 – 29.9%), mean long T2* was 9.2 ms (95% CI, 5.1 – 13.3 ms), and mean single-component T2* was 2.5 ms (95% CI, 1.8 – 3.1 ms).
Discussion: 2D UTE MRI with bi-component and single-component T2* analysis was successfully implemented. Inter-individual variation can be demonstrated in grossly and histologically normal Achilles tendons.
Materials and methods: six tendon samples which were grossly normal on visual inspection and palpation were harvested. A 2D UTE pulse sequence was implemented on a 3T MR scanner and bicomponent and single-component T2* analysis was performed. Tendon samples were histologically processed and evaluated.
Results: mean short T2* fraction was 79.2% (95% confidence interval [CI],70.1 – 88.3%), mean short T2* was 1.8 ms (95% CI, 1.3 – 2.3 ms), mean long T2* fraction was 20.8% (95% CI, 11.7 – 29.9%), mean long T2* was 9.2 ms (95% CI, 5.1 – 13.3 ms), and mean single-component T2* was 2.5 ms (95% CI, 1.8 – 3.1 ms).
Discussion: 2D UTE MRI with bi-component and single-component T2* analysis was successfully implemented. Inter-individual variation can be demonstrated in grossly and histologically normal Achilles tendons.
KEY WORDS: tendon, ultrashort TE, bi-component analysis.